ANALYZER PULSED MAGNETIC MULTIPARAMETER I-


PURPOSE

      The IMA-M (MA-M) pulsed magnetic multiparameter analyzer is designed for nondestructive testing of hardness of articles in machine-building, produced of medium-carbon and alloyed steels after volumetric hardening, after low-temperature, medium-temperature and high-temperature annealing.

OPERATION PRINCIPLE

      The operating principle of the IMA-M Analyzer consists in local magnetization of the article under test by series of varying in amplitude and direction pulses of magnetic field, induced by superimposed solenoid, in measurement of the parameters of the magnetic hysteresis loop on the gradient of the normal component of the residual magnetization field strength and in transforming them to the values of hardness on the in advance created multiple correlation connection.

CONSTRUCTION

      The device IMA-M is designed as a portable one consisting from the electronic unit and the transducer, connected by the electrical cable with the length of 1,5 meters.

SPECIFICATIONS

Maximum amplitude of magnetic field pulses on the end face of a solenoid, ps, /m

(5,2; 5,9; 6,5; 7,2; 7,8)x105

The step of change of the pulse amplitude, Dp, /m

1/9ps 5%

The measuring range of the gradient of normal component of the residual magnetization field strength, /m2

(1 - 250)103

The relative measuring error, %, not higher

5

Presentation of the HRC or HB hardness measuring results

digital

The duration of a single measurement, s, not more

30

Overall dimensions, mm, not more:

- electronic unit

480x360x170

- transducer

56x56x165

Weight, kg, not more:

- electronic unit

16

- transducer

0,6